Stack-based buffer overflow in the save method in the IntegraXor.Project ActiveX control in igcomm.dll in Ecava IntegraXor Human-Machine Interface (HMI) before 3.5.3900.10 allows remote attackers to execute arbitrary code via a long string in the second argument.
A SQL Injection issue was discovered in Ecava IntegraXor Versions 5.2.1231.0 and prior. The application fails to properly validate user input, which may allow for an unauthenticated attacker to remotely execute arbitrary code in the form of SQL queries.
An issue was discovered in Ecava IntegraXor Version 5.0.413.0. The Ecava IntegraXor web server has parameters that are vulnerable to SQL injection. If the queries are not sanitized, the host's database could be subject to read, write, and delete commands.
Directory traversal vulnerability in an unspecified ActiveX control in Ecava IntegraXor before 3.71.4200 allows remote attackers to execute arbitrary code via vectors involving an HTML document on the server.
Multiple buffer overflows in an ActiveX control in PE3DO32A.ocx in IntegraXor SCADA Server 4.00 build 4250.0 and earlier allow remote attackers to execute arbitrary code via a crafted HTML document.
The HMI web server in Ecava IntegraXor before 5.0 build 4522 allows remote attackers to obtain sensitive cleartext information by sniffing the network.
Ecava IntegraXor HMI before n 3.60 (Build 4032) allows remote attackers to bypass authentication and execute arbitrary SQL statements via unspecified vectors related to a crafted POST request. NOTE: some sources have reported this issue as SQL injection, but this might not be accurate.
Untrusted search path vulnerability in Ecava IntegraXor 3.6.4000.0 allows local users to gain privileges via a Trojan horse dwmapi.dll file in the current working directory. NOTE: the provenance of this information is unknown; the details are obtained solely from third party information.
Cross-site scripting (XSS) vulnerability in Ecava IntegraXor before 5.0 build 4522 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.
CRLF injection vulnerability in Ecava IntegraXor before 5.0 build 4522 allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via a crafted URL.
A SQL Injection issue was discovered in Ecava IntegraXor v 6.1.1030.1 and prior. The SQL Injection vulnerability has been identified, which generates an error in the database log.
A SQL Injection issue was discovered in Ecava IntegraXor v 6.1.1030.1 and prior. The SQL Injection vulnerability has been identified, which an attacker can leverage to disclose sensitive information from the database.
Directory traversal vulnerability in Ecava IntegraXor 3.6.4000.0 and earlier allows remote attackers to read arbitrary files via a .. (dot dot) in the file_name parameter in an open request.
Untrusted search path vulnerability in Ecava IntegraXor SCADA Server before 4.2.4488 allows local users to gain privileges via a renamed DLL in the default install directory.
Multiple cross-site scripting (XSS) vulnerabilities in Ecava IntegraXor before 3.60 (Build 4080) allow remote attackers to inject arbitrary web script or HTML via unspecified vectors.
Ecava IntegraXor before 5.0 build 4522 does not include the HTTPOnly flag in a Set-Cookie header for the session cookie, which makes it easier for remote attackers to obtain potentially sensitive information via script access to this cookie.
Published 2016-04-22 · Modified
4.3EPSS 0.011
Demo
ThreatFusionAI™ Product Walkthrough
The fastest way to see what ThreatFusionAI does is to run a search. Paste any hash, IP, domain or CVE and you'll get the full report, the connected indicators and the actor attribution in one pass.
What you'll see
• Verdicts from multiple antivirus engines
• The connected IOC graph you can click through
• Ranked threat actors based on ATT&CK overlap
Next step
Start with a free search, no card needed. Check the plans if you need more volume.
ThreatFusionAI AssistantAI help & guidance
AI assistant — can make mistakes. Verify important results.