VendorsOraclesun_zfs_storage_appliance_kit_software2013
Vulnerabilities

Oracle Sun ZFS Storage Appliance Kit Software 2013

Ranked by severity, then by exploit likelihood. Click a CVE ID for its full record.

3CVEs
CVE-2017-3578
Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: RAS subsystems). The supported version that is affected is AK 2013. Easily "exploitable" vulnerability allows low privileged attacker with logon to the infrastructure where Sun ZFS Storage Appliance Kit (AK) executes to compromise Sun ZFS Storage Appliance Kit (AK). While the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H).
Published 2017-04-24 · Modified
8.8EPSS 0.004
CVE-2017-10013
Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Sun ZFS Storage Appliance Kit (AK), attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H).
Published 2017-08-08 · Modified
8.3EPSS 0.019
CVE-2017-10016
Vulnerability in the Sun ZFS Storage Appliance Kit (AK) component of Oracle Sun Systems Products Suite (subcomponent: User Interface). The supported version that is affected is AK 2013. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Sun ZFS Storage Appliance Kit (AK). Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in takeover of Sun ZFS Storage Appliance Kit (AK). CVSS 3.0 Base Score 7.5 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H).
Published 2017-08-08 · Modified
7.6EPSS 0.019