VendorsSchneider Electricmodicon_quantum_140noc78100_firmwareall versions
Vulnerabilities

Schneider Electric Schneider-Electric Modicon Quantum 140NOC78100 Firmware

Ranked by severity, then by exploit likelihood. Click a CVE ID for its full record.

4CVEs
CVE-2020-7564
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause write access and the execution of commands when uploading a specially crafted file on the controller over FTP.
Published 2020-11-18 · Modified
8.8EPSS 0.011
CVE-2020-7563
A CWE-787: Out-of-bounds Write vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause corruption of data, a crash, or code execution when uploading a specially crafted file on the controller over FTP.
Published 2020-11-18 · Modified
8.8EPSS 0.011
CVE-2020-7562
A CWE-125: Out-of-Bounds Read vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause a segmentation fault or a buffer overflow when uploading a specially crafted file on the controller over FTP.
Published 2020-11-18 · Modified
8.1EPSS 0.009
CVE-2022-37301
A CWE-191: Integer Underflow (Wrap or Wraparound) vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU (part numbers BMXP34*)(V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*)(V3.22 and prior), Legacy Modicon Quantum/Premium(All Versions), Modicon Momentum MDI (171CBU*)(All Versions), Modicon MC80 (BMKC80)(V1.7 and prior)
Published 2022-11-22 · Modified
7.5EPSS 0.008