VendorsSiemensek-ertec_200pany version
Vulnerabilities

Siemens Ek-ertec 200p any version

Ranked by severity, then by exploit likelihood. Click a CVE ID for its full record.

4CVEs
CVE-2017-12741
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.
Published 2017-12-26 · Modified
8.7EPSS 0.033
CVE-2019-13946
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device.
Published 2020-02-11 · Modified
7.8EPSS 0.015
CVE-2019-10936
Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition.
Published 2019-10-10 · Modified
7.5EPSS 0.021
CVE-2019-10923
An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
Published 2019-10-10 · Modified
7.5EPSS 0.014