VendorsSiemensscalance_sc-600any version
Vulnerabilities

Siemens SCALANCE SC-600 any version

Ranked by severity, then by exploit likelihood. Click a CVE ID for its full record.

6CVEs
CVE-2022-36323
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.
Published 2022-08-10 · Modified
9.1EPSS 0.017
CVE-2018-5391
The Linux kernel, versions 3.9+, IP implementation is vulnerable to denial of service conditions with low rates of specially modified packets
Published 2018-09-06 · Modified
7.8EPSS 0.324
CVE-2021-25676
A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions >= V2.1 and < V2.1.3). Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions. When triggered, the device will reboot automatically.
Published 2021-03-15 · Modified
7.5EPSS 0.013
CVE-2022-36325
Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.
Published 2022-08-10 · Modified
6.8EPSS 0.009
CVE-2019-10928
A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device.
Published 2019-08-13 · Modified
6.6EPSS 0.004
CVE-2021-3449
NULL pointer deref in signature_algorithms processing
Published 2021-03-25 · Modified
5.9EPSS 0.635