VendorsTriangle MicroWorksscada_data_gatewayany version
Vulnerabilities

Triangle MicroWorks SCADA Data Gateway any version

Ranked by severity, then by exploit likelihood. Click a CVE ID for its full record.

7CVEs
CVE-2020-10611
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
Published 2020-04-15 · Modified
9.8EPSS 0.052
CVE-2023-2186
On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string vulnerability to repeatedly crash the GTWWebMonitor.exe process to DoS the Web Monitor. Furthermore, an authenticated user can leverage this vulnerability to leak memory from the GTWWebMonitor.exe process. This could be leveraged in an exploit chain to gain code execution.
Published 2023-06-07 · Modified
9.8EPSS 0.007
CVE-2020-10615
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.
Published 2020-04-15 · Modified
7.5EPSS 0.026
CVE-2020-10613
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
Published 2020-04-15 · Modified
7.5EPSS 0.025
CVE-2023-2187
On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send broadcast events to any user via the WebMonitor.An unauthenticated user can use this vulnerability to forcefully log out of any currently logged-in user by sending a "password change event". Furthermore, an attacker could use this vulnerability to spam the logged-in user with false events.
Published 2023-06-07 · Modified
5.3EPSS 0.006
CVE-2014-2342
Triangle MicroWorks SCADA Data Gateway Resource Exhaustion
Published 2014-05-30 · Modified
5.0EPSS 0.018
CVE-2014-2343
Triangle MicroWorks SCADA Data Gateway Resource Exhaustion
Published 2014-05-30 · Modified
2.1EPSS 0.003