VendorsHitachi Energymicroscada_x_sys600all versions
Vulnerabilities

Hitachi Energy MicroSCADA X SYS600

Ranked by severity, then by exploit likelihood. Click a CVE ID for its full record.

19CVEs
CVE-2024-3980
The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. If exploited the vulnerability allows the attacker to access or modify system files or other files that are critical to the application.
Published 2024-08-27 · Analyzed
9.9EPSS 0.006
CVE-2024-4872
A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit this vulnerability an attacker must have a valid credential.
Published 2024-08-27 · Analyzed
9.9EPSS 0.005
CVE-2024-7940
The product exposes a service that is intended for local only to all network interfaces without any authentication.
Published 2024-08-27 · Analyzed
9.8EPSS 0.006
CVE-2022-29490
A vulnerability exists in the Workplace X WebUI in which an authenticated user is able to execute any MicroSCADA internal scripts irrespective of the authenticated user's role.
Published 2022-09-12 · Modified
8.8EPSS 0.006
CVE-2022-3388
Input Validation Vulnerability in Hitachi Energy’s MicroSCADA Pro/X SYS600 Products
Published 2022-11-21 · Modified
8.8EPSS 0.003
CVE-2025-39204
A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product. The filtering query in the Web interface can be malformed, so returning data can leak unauthorized information to the user.
Published 2025-06-24 · Analyzed
8.5EPSS 0.003
CVE-2026-9853
A vulnerability exists in SYS600 which allows any user authenticated to the operating system of the server hosting the application to read and modify application objects without being authenticated to the SYS600 system itself. Only the SYS600 system users should be permitted to view and modify application objects.
Published 2026-09-03 · Analyzed
8.5EPSS 0.001
CVE-2026-9854
A vulnerability exists in SYS600 RBAC mechanism where users having access to the engineering tools could elevate their privileges to administrator level on the underlying Windows host, granting themselves full control over the host machine.
Published 2026-09-03 · Analyzed
8.5EPSS 0.001
CVE-2025-39202
A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data corruption.
Published 2025-06-24 · Analyzed
8.3EPSS 0.002
CVE-2024-3982
An attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already established session. By default, the session logging level is not enabled and only users with administrator rights can enable it.
Published 2024-08-27 · Analyzed
8.2EPSS 0.002
CVE-2026-9852
A CSV injection vulnerability exists in SYS600. Injected malicious formulas can add or modify data to the spreadsheet, insert links, exfiltrate data, and in some cases, depending on how the user has their environment configured, execute malicious code on the user’s machine. To exploit this issue attackers would need a way to create arbitrary log messages. This could be achieved through normal functionality via SCIL scripts, a log injection vulnerability, or via the SYS600 broker. This vulnerability affects all Windows users regardless of their privilege level who can run the Notify service and export the log.
Published 2026-09-03 · Analyzed
7.8EPSS 0.002
CVE-2022-29922
A vulnerability exists in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS ...
Published 2022-09-14 · Modified
7.5EPSS 0.008
CVE-2022-2277
A vulnerability exists in the ICCP stack of the affected SYS600 versions due to validation flaw in the process that establishes the ICCP communication. The validation flaw will cause a denial-of-service when ICCP of SYS600 is request to forward any da ...
Published 2022-09-14 · Modified
7.5EPSS 0.008
CVE-2022-29492
A vulnerability exists in the handling of a malformed IEC 104 TCP packet. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected conne ...
Published 2022-09-14 · Modified
7.5EPSS 0.007
CVE-2022-1778
A vulnerability exists during the start of the affected SYS600, where an input validation flaw causes a buffer-overflow while reading a specific configuration file. Subsequently SYS600 will fail to start. The configuration file can only be accessed by ...
Published 2022-09-14 · Modified
7.5EPSS 0.005
CVE-2025-39203
A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. An IEC 61850-8 crafted message content from IED or remote system can cause a denial of service resulting in disconnection loop.
Published 2025-06-24 · Analyzed
7.1EPSS 0.002
CVE-2025-39205
A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. The certificate validation of the TLS protocol allows remote Man-in-the-Middle attack due to missing proper validation.
Published 2025-06-24 · Analyzed
7.1EPSS 0.002
CVE-2025-39201
A vulnerability exists in MicroSCADA X SYS600 product. If exploited this could allow a local unauthenticated attacker to tamper a system file, making denial of Notify service.
Published 2025-06-24 · Analyzed
6.9EPSS 0.001
CVE-2024-7941
An HTTP parameter may contain a URL value and could cause the web application to redirect the request to the specified URL. By modifying the URL value to a malicious site, an attacker may successfully launch a phishing scam and steal user credentials.
Published 2024-08-27 · Analyzed
4.3EPSS 0.003