VendorsNiteststandall versions
Vulnerabilities

Ni National Instruments teststand

Ranked by severity, then by exploit likelihood. Click a CVE ID for its full record.

3CVEs
CVE-2013-5022
Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allows remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method, in conjunction with file content in the (1) Caption or (2) FormatString property value.
Published 2013-08-06 · Modified
10.0EPSS 0.026
CVE-2013-5021
Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.
Published 2013-08-06 · Modified
9.3EPSS 0.021
CVE-2013-5023
The ActiveX controls in the HelpAsst component in NI Help Links in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allow remote attackers to cause a denial of service by triggering the display of local .chm files.
Published 2013-08-06 · Modified
4.3EPSS 0.013