VendorsSchneider Electricsage_1430all versions
Vulnerabilities

Schneider Electric Sage 1430

Ranked by severity, then by exploit likelihood. Click a CVE ID for its full record.

8CVEs
CVE-2024-37036
CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass when sending a malformed POST request and particular configuration parameters are set.
Published 2024-06-12 · Modified
9.8EPSS 0.005
CVE-2024-37038
CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated user with access to the device’s web interface to perform unauthorized file and firmware uploads when crafting custom web requests.
Published 2024-06-12 · Modified
8.8EPSS 0.004
CVE-2024-37037
CWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path Traversal’) vulnerability exists that could allow an authenticated user with access to the device’s web interface to corrupt files and impact device functionality when sending a crafted HTTP request.
Published 2024-06-12 · Modified
8.1EPSS 0.010
CVE-2024-37040
CWE-120: Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’) vulnerability exists that could allow a user with access to the device’s web interface to cause a fault on the device when sending a malformed HTTP request.
Published 2024-06-12 · Modified
8.1EPSS 0.004
CVE-2024-5560
CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the device’s web interface when an attacker sends a specially crafted HTTP request.
Published 2024-06-12 · Modified
7.5EPSS 0.009
CVE-2024-37039
CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request.
Published 2024-06-12 · Modified
7.5EPSS 0.008
CVE-2015-3963
Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnet_coreip 1.2.2.0, as used on Schneider Electric SAGE RTU devices before J2 and other devices, does not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value.
Published 2015-08-04 · Modified
5.8EPSS 0.037
CVE-2015-6485
Schneider Electric Telvent Sage 2300 RTUs with firmware before C3413-500-S01, and LANDAC II-2, Sage 1410, Sage 1430, Sage 1450, Sage 2400, and Sage 3030M RTUs with firmware before C3414-500-S02J2, allow remote attackers to obtain sensitive information from device memory by reading a padding field of an Ethernet packet.
Published 2016-03-12 · Modified
5.3EPSS 0.012