VendorsSiemensscalance_m-800_firmwareall versions
Vulnerabilities

Siemens Scalance m-800 Firmware

Ranked by severity, then by exploit likelihood. Click a CVE ID for its full record.

13CVEs
CVE-2017-14491
Heap-based buffer overflow in dnsmasq before 2.78 allows remote attackers to cause a denial of service (crash) or execute arbitrary code via a crafted DNS response.
Published 2017-10-02 · Modified
9.81 PoCEPSS 0.849
CVE-2022-36323
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.
Published 2022-08-10 · Modified
9.1EPSS 0.017
CVE-2021-25667
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.
Published 2021-03-15 · Modified
8.8EPSS 0.009
CVE-2020-28400
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.
Published 2021-07-13 · Modified
8.7EPSS 0.019
CVE-2018-5391
The Linux kernel, versions 3.9+, IP implementation is vulnerable to denial of service conditions with low rates of specially modified packets
Published 2018-09-06 · Modified
7.8EPSS 0.324
CVE-2019-13946
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device.
Published 2020-02-11 · Modified
7.8EPSS 0.015
CVE-2022-36324
Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.
Published 2022-08-10 · Modified
7.5EPSS 0.017
CVE-2021-25676
A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions >= V2.1 and < V2.1.3). Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions. When triggered, the device will reboot automatically.
Published 2021-03-15 · Modified
7.5EPSS 0.013
CVE-2017-2680
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
Published 2017-05-11 · Modified
7.1EPSS 0.011
CVE-2017-2681
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
Published 2017-05-11 · Modified
7.1EPSS 0.009
CVE-2022-36325
Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.
Published 2022-08-10 · Modified
6.8EPSS 0.009
CVE-2021-3449
NULL pointer deref in signature_algorithms processing
Published 2021-03-25 · Modified
5.9EPSS 0.635
CVE-2016-7090
The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an http session.
Published 2016-09-29 · Modified
4.3EPSS 0.019